Polycom Wireless Server 6000 Technické informace Strana 163

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 198
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 162
KIRK Wireless Server 6000 Installation and Configuration Guide
15–23
1 From the Display filter list you can select between emergency, critical,
error, warning, notice, info or debug depending on the logs you want to
see.
The different types of status are:
— Emergency is used for errors causing the system to malfunction for all
calls
— Critical is used for events which do not occur under normal operation,
which cause major malfunction. E.g. events that result in a permanent
state of malfunction for a handset
— Error is used for events which do not occur under normal operation,
which cause minor malfunction. E.g. events that result in a lost call
— Warning is used for events which do not occur under normal
operation, which may cause malfunction. E.g. events that may result
in a lost call
— Notice is used for events which occur under normal operation and
are relevant for an administrator. E.g. KGAP started
— Information is used for events which occur under normal operation
and may be relevant for an administrator. E.g new RFP connection
— Debug is used for debug information
2 Click Status, and then click Logs.
3 Click Save if you want to save the logs in a file.
A Save As dialog box appears.
Figure 15-31 Adm. Page: Save As dialog box
Zobrazit stránku 162
1 2 ... 158 159 160 161 162 163 164 165 166 167 168 ... 197 198

Komentáře k této Příručce

Žádné komentáře